Position sensors and object recognition Fluid sensors and diagnostic systems
DKD and ISO calibration of temperature sensors. efector octavis - the new approach in machine diagnosis. Intelligent temperature sensors with IO-Link. Intuitive handling: Temperature sensors from ifm. Profibus PA pressure transmitter now also with ATEX approval. Pt100 probe sensors with 4-wire connection. Tried-and-tested pressure sensor for a new area of application. New generation of electronic point level sensors. Programming and display unit for IO-Link and EPS sensors. efector octavis - the new approach in machine diagnosis. New submersible pressure transmitter for hydrostatic level measurement. Optimised pressure transmitter with improved accuracy. The microwave sensor – it is all about the echo! Real-time maintenance with efector octavis. Vibration sensor efector octavis. Temperature measurement without calibration – now with Profibus PA. Magnetic-inductive inline flow sensor. Compact temperature sensor efector octavis – the new approach in machine diagnosis. Intuitive handling: Temperature sensors from ifm. Pt1000 probe sensors with new technology. Temperature transmitter with excellent response time. Archive
Bus system AS-Interface Control systems Identification systems

 
Flow rate measurement for low flow of gases.
 
 

 
Thermal measuring principle for air or N2, CO2 and argon.
  • High accuracy and repeatability in the measuring range.
  • Integrated totaliser for measuring the total consumption.
  • 4-digit 10-segment display: clearly legible at large distances.
  • Freely selectable output functions: binary, analogue and pulse.
  • Short response time and great measurement dynamics.
The success story continues
Following the successful market launch of the efector metris series there are now two further versions. One of the versions is used for pure measurement of the compressed air consumption and the other reliably detects gases such as argon, carbon dioxide or nitrogen.

Measuring small quantities
Both units serve for the measurement and detection of small consumed quantities up to 24.54 Nm3/h. So, smallest quantities can be precisely dosed, controlled and monitored.

Monitoring and documentation
Due to the integrated totaliser these units enable longterm detection and documentation of consumed total quantities. The measured data is output via the analogue or pulse output.

SD5000 - Measuring range 0.06...15.00 Nm³/h
SD5100 - Measuring range 0.047...24.54 Nm³/h

Further information: Bulletin (PDF-file 281 kB).