Inductive proximity switches for hazardous dust areas II 3D. |
|
| |
|
 |
|
| |
|

|
|
Rectangular designs (for use in zone 22, non-conductive dusts). Applications These units are suitable for use in zone 22 hazardous areas with non-conductive dusts according to the category 3D. The design of the proximity switches complies, among others, with the standards EN 50014 und EN 50281-1-1.
The family of units The rectangular sensors in tried-and-tested plastic housings are available in different sizes from 40 x 12 x 26 mm to 105 x 80 x 40 mm. The range covers dual switches for the detection of valve positions to sensors with extra long sensing ranges for the monitoring of elevators.
Connection options Units with cable have a 2 m long PVC cable. For the units with M12 connector a locking device (separate order no. E11532) is available which ensures that the connector can only be loosened with the aid of a tool. Units with terminal chamber are fitted with an ATEX-compliant cable gland.
IN503A - Schaltabstand 4 nf, DC PNP 3-wire, PVC-cable 2m
IM502A - sensing range 20 nf, DC PNP 3-wire, terminals
ID500A - sensing range 60 nf, DC PNP 3-wire, terminals
IN500A - sensing range 4 nf, DC PNP 4-wire, M12-connector
IM500A - sensing range 35 nf, DC PNP 4-wire, M12-connector
IC000A - sensing range 40 nf, AC/DC 3-wire, terminals Further Information: Bulletin (PDF-File 210 kB).
|
|
|
|