ecolink M12 - the safe connection even in difficult applications. ecolink M12, the safe connection even in ATEX applications. MAXIpower in miniFormat. Now also with laser class 1. New photoelectric design OG-Cube in metal housing with M18 thread. Automation package for rising stem valves. Cylinder sensors for short-stroke cylinders. Full metal inductive sensors: simply unbeatable! M18 laser sensors for highest precision in laer class 1. O5 contrast sensor - for a splash of colour! Open the floodgates! The new OG wetline. Precise C-slot cylinder sensors. Precise type O5 laser sensor with laser class 1. The height of level detection. Fail-safe inductive sensors directly detect metal. M12 ecolink – for applications in particularly harsh environments. Backlights for contour and orientation verification. Detection of conductive media through a wall. PMD technology now also with laser protection class 1 Full metal housing inductive sensors for heavy duty. Full metal inductive sensors for the food industry. OG family on the leash. Optimum cylinder sensors for short-stroke cylinders. efector dualis image sensor Archive
Fluid sensors and diagnostic systems Bus system AS-Interface Control systems Identification systems

 
Inductive proximity switches for hazardous dust areas II 3D.
 
 

 
Rectangular designs (for use in zone 22, non-conductive dusts).

Applications
These units are suitable for use in zone 22 hazardous areas with non-conductive dusts according to the category 3D. The design of the proximity switches complies, among others, with the standards EN 50014 und EN 50281-1-1.

The family of units
The rectangular sensors in tried-and-tested plastic housings are available in different sizes from 40 x 12 x 26 mm to 105 x 80 x 40 mm. The range covers dual switches for the detection of valve positions to sensors with extra long sensing ranges for the monitoring of elevators.

Connection options
Units with cable have a 2 m long PVC cable. For the units with M12 connector a locking device (separate order no. E11532) is available which ensures that the connector can only be loosened with the aid of a tool. Units with terminal chamber are fitted with an ATEX-compliant cable gland.

 IN503A - Schaltabstand 4 nf, DC PNP 3-wire, PVC-cable 2m
 IM502A - sensing range 20 nf, DC PNP 3-wire, terminals
 ID500A - sensing range 60 nf, DC PNP 3-wire, terminals
 IN500A - sensing range 4 nf, DC PNP 4-wire, M12-connector
 IM500A - sensing range 35 nf, DC PNP 4-wire, M12-connector
 IC000A - sensing range 40 nf, AC/DC 3-wire, terminals

Further Information: Bulletin (PDF-File 210 kB).